1.
Align the node on the slide rails and push the node fully into the rack. Secure the node to the front
mounting flanges with the captive thumbscrews (
1
in Figure 42).
2.
Reconnect the fibre-channel and Ethernet cables. Ensure that you replace the fibre-channel and
Ethernet cables in the same ports from which they were removed.
3.
Replace the cable-retention bracket. See “Replacing the cable-retention bracket” on page 34.
Replacing the SAN Volume Controller 2145-8G4 in a rack
Follow these instructions when you are prompted to replace the SAN Volume Controller 2145-8G4.
Attention:
Do not touch the power control switches on adjacent SAN Volume Controller nodes when
you remove or install SAN Volume Controller nodes in a rack. Touching these switches on adjacent SAN
Volume Controller nodes might cause those devices to turn off and make customer data inaccessible.
Perform the following steps to replace the SAN Volume Controller 2145-8G4 in a rack:
1.
Fully extend the support slides.
2.
Align the node on the slide rails and push the node fully into the rack. Secure the node to the front
mounting flanges with the captive thumbscrews (
1
in Figure 43 on page 53).
Figure 42. The captive thumbscrews that secure the node and the shipping brackets
52
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...