Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a
static-protected mat or surface. For more information, see “Handling static-sensitive devices” on page xix.
Important:
You can hot swap a fan. However, using MAP 5350 to power off the node through proven
methods avoids risking an abrupt power failure on the node, which avoids the possible corruption of
data.
Perform the following steps to remove a failed fan:
1.
Read the safety information to which “Preparing to remove and replace parts” on page 20 refers.
2.
Optional: Follow the procedure in MAP 5350 in the
IBM System Storage SAN Volume Controller 2145
Troubleshooting Guide
to verify that the node data is mirrored and synchronized, and that there are no
dependent volumes before turning off the node.
Important:
If you decide to hot swap the fan, use MAP 5350 to make all of the necessary checks that
ensure that the partner node in the I/O group can take over all I/O group operations, if necessary,
and that there are no dependent VDisks on the node. With the partner node available and no
dependent VDisks on the node, you do not lose access to data if this node accidentally powers off.
3.
Slide the node forward to remove the cover and expose the fans, as described in “Removing the SAN
Volume Controller 2145-CF8 top cover” on page 68.
Figure 232 shows fan locations within the SAN Volume Controller 2145-CF8 node.
1
Fan 1
2
Fan 2
3
Fan 3
4
Fan 4
5
Fan 5
6
Fan 6
7
Fan tabs
7
5
6
8
9
10
1
2
3
4
Figure 232. SAN Volume Controller 2145-CF8 fan locations and connectors
210
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...