Table 3. FRUs in the SAN Volume Controller 2145-CF8 parts assembly (continued)
Assembly
index
Part number
Units
Description
-13
44E8690
1
Disk controller
SAS controller card for the SAS 2.5 inch disk drive that also
includes the riser card.
-14
44E8690
1
Disk controller / USB riser card
Riser card that connects the disk controller to the system board
and provides the USB port to which the service controller cable
connects.
-15
46D1266
1
Microprocessor
2.40 GHz Quad-core microprocessor
Note:
This part is the microprocessor only. When replaced, you
must also have alcohol wipes and thermal grease.
-
31P1338
4
Short-wave SFP transceivers
Small form-factor pluggable (SFP) fibre-channel transceiver that
provides an auto-negotiating 2, 4, or 8 gigabits-per-second
short-wave optical connection on the 4-port fibre-channel adapter.
Note:
It is possible that SFP transceivers other than those shipped
with the product are in use on the fibre-channel host bus adapter.
It is a customer responsibility to obtain replacement parts for such
SFP transceivers. The FRU part number is shown as “Non
standard - supplied by customer” in the vital product data.
-
31P1206
1
Service controller cable
The USB cable used to connect the service controller to the system
board.
-
43V6922
1
Disk signal cable
200 mm SAS disk signal cable
-
46C4148
1
Disk power cable
SAS disk power cable
-
31P1294
1
Power cable assembly
The cable assembly that connects the SAN Volume Controller and
the 2145 UPS-1U. The assembly consists of two power cables
bundled with a serial cable.
-
49Y4817
1
Cable-management arm
-
46C4139
1
Operator information panel cable
Cable that connects the operator information panel to the system
board
-
41Y9292
-
Thermal grease
Grease that helps provide a thermal seal between the processor
and the heat sink
-
59P4739
-
Alcohol wipe
Cleaning wipe
4
IBM SAN Volume Controller Hardware Maintenance Guide
1
1
1
1
1
1
1
1
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...