1
Solid-state drive (SSD)
2
Drive handle
The system error LED and the DASD diagnostics panel LED turn on when a solid-state drive
(SSD) is removed from a drive bay. The system error LED and the DASD diagnostics panel LED
turn off when the SSD is replaced in the drive bay. If you do not replace the SSD in the same
drive bay, the system error LED and the DASD diagnostics panel LED remain lit. To clear the
system error LED and the DASD diagnostics panel LED, turn off the node using the instructions
given in MAP 5350 in the
IBM System Storage SAN Volume Controller 2145 Troubleshooting Guide
and remove both power cables.
7.
If you are not replacing the drive right away, install a drive-bay blank electromagnetic compatibility
(EMC) filler assembly into the empty drive bay.
The electromagnetic interference (EMI) integrity and cooling of the node are protected by having all
bays and PCI slots covered or occupied. When you install a drive, save the drive bay blank EMC
filler assembly from the drive bay to cover any later removal of the device.
8.
If you are removing additional hot-swap solid-state drives (SSDs), do so now.
9.
If you are replacing drives, replace them now, as described in “Replacing a SAN Volume Controller
2145-CF8 solid-state drive (SSD).”
10.
If you are instructed to return the drive assembly, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Replacing a solid-state drive (SSD)
You can replace solid-state drives (SSDs) in the SAN Volume Controller 2145-CF8.
Replacing a SAN Volume Controller 2145-CF8 solid-state drive (SSD)
You can replace an installed solid-state drive (SSD) on a SAN Volume Controller 2145-CF8 node.
If you are installing a high-speed SAS adapter (feature code 4500) and one or more solid-state drives
(SSDs) (feature code 4601), use the instructions that come with each MES upgrade to install and configure
the high-speed SAS adapter and each solid-state drive (SSD).
This procedure describes how to replace a solid-state drive (SSD) that was installed and configured, but
then removed.
The SAN Volume Controller 2145-CF8 node supports from one to four 2.5-inch SSDs in addition to the
required boot drive that ships with the node.
To replace the SAN Volume Controller 2145-CF8 disk drive, perform the following steps:
1.
Read the safety information to which “Preparing to remove and replace parts” on page 20 refers.
2.
Make sure that the node cover is in place and fully closed.
1
2
Figure 114. Solid-state drive (SSD) for the SAN Volume Controller 2145-CF8
Chapter 2. Removing and replacing parts
113
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...