Wait one minute. If
Cluster:
cluster_name
is displayed, the node has rejoined the cluster. If
Cluster:
does not display, see "MAP 5000" in the
IBM System Storage SAN Volume Controller 2145 Troubleshooting
Guide
to determine how to solve this problem or contact the IBM support center.
Replacing the SAN Volume Controller 2145-8A4 service controller
Use the following information to replace the SAN Volume Controller 2145-8A4 service controller.
To replace the service controller, perform the following steps:
1.
Gently push the service controller (shown in Figure 89) into the frame until the rear connectors are
fully seated and the service controller front metal work is up to the frame.
2.
Connect the power cable to the node and replace the cable-retention bracket. See “Replacing the
cable-retention bracket” on page 34.
Note:
If you replaced the service controller as part of concurrent maintenance, you must rewrite the
WWNN on the new service controller. If you do not, and the fibre-channel switch zoning uses
WWPNs, you cannot add the node back into the cluster until the fibre-channel switches in the SAN
are re-zoned. Also, the host systems cannot access the fibre-channel ports on that node until the host
systems are rebooted.
To restore the WWNN, perform the following steps:
a.
Determine the WWNN for the node by examining the vital product data (VPD) of the node or the
zoning that is defined in the SAN switch. Record the last five numbers of the WWNN for the
node that you are working on.
b.
Start the node by performing a node rescue.
c.
Change the node WWNN by performing the following steps:
svc00471
Figure 89. SAN Volume Controller 2145-8A4 service controller
88
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...