1.
Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350 in the
IBM System Storage SAN Volume Controller 2145 Troubleshooting Guide
for more information.
2.
3.
Remove the heat sink (
1
in Figure 248). Loosen two captive screws on alternate sides of the heat
sink fully before loosening the other two captive screws. (This helps to break the bond between the
heat sink and the microprocessor.) After the captive screws are loosened, remove the heat sink.
1
Heat sink
2
Heat sink installation label
3
Microprocessor
4
Alignment indicator
4.
Open the microprocessor release lever (
1
in Figure 249) to the fully open position.
1
Microprocessor release lever
2
Microprocessor bracket frame
5.
Open the microprocessor bracket frame (
2
in Figure 249).
6.
Carefully remove the microprocessor from the socket. Be careful to only touch the edges of the
microprocessor.
svc00285
1
3
4
2
Figure 248. Removing the heat sink from the microprocessor
1
2
svc00288
Figure 249. The microprocessor release lever and bracket frame fully opened
226
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...