1
Fibre-channel adapter
2
Adapter support bracket
3
Riser-card-adapter connector
4
Riser-card assembly
5
System-board-riser-card connector
2.
Replace the top cover. See “Replacing the top cover” on page 72.
3.
Place the node in the rack. See “Replacing the SAN Volume Controller in a rack” on page 48.
4.
Replace the cables that were removed from the node, and make sure that you replace the
fibre-channel cables in the same ports from which they were removed.
5.
Replace the cable-retention bracket. See “Replacing the cable-retention bracket” on page 34.
Replacing the SAN Volume Controller 2145-8F4 or SAN Volume Controller
2145-8F2 adapter assemblies
Perform the following steps to install the fibre-channel card into the riser-card assembly:
Note:
The adapter assemblies are electrostatic-discharge sensitive. Take precautions to avoid damage
from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface. For more
information, see “Handling static-sensitive devices” on page xix.
1.
Install the fibre-channel card in slot 1, which is shown in Figure 187.
a.
Slide the I/O connector portion of the adapter through the slot 1 opening and align the edge
connector on the low-profile adapter with the connector on the riser card. Press the edge connector
firmly into the riser-card connector. Make sure that the adapter snaps into the riser card securely
and the adapter is lying on top of the low-profile adapter support.
2
svc00253
1
Figure 186. Replacing the riser-card assembly for the SAN Volume Controller 2145-8G4
svc00100
1
Figure 187. SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 PCI slot 1 card retainer
Chapter 2. Removing and replacing parts
171
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...