1)
On the front-panel display, press and release the down button until the Node panel is
displayed. Then press and release the right button until the Node WWNN: panel is displayed.
2)
Press and hold the down button, press and release the select button, and then release the down
button. The display switches into edit mode.
Edit WWNN
is displayed on line 1. Line 2 of the
display shows the last five numbers of the WWNN that is currently set. The first number is
highlighted.
3)
Change the highlighted number to match the number from the VPD or from customer zoning.
Use the up and down buttons to increase or decrease the numbers. The numbers wrap F to 0
or 0 to F. Use the left and right buttons to move between the numbers.
4)
When the displayed value matches the numbers in the VPD or customer zoning, press and
release the select button to accept the numbers. The Node WWNN: panel is displayed and the
second line shows the last five numbers of the restored WWNN.
Wait one minute. If
Cluster:
is displayed on the front panel, this indicates that the node is ready to be
added to the cluster. If
Cluster:
does not display, see MAP 5000 in the
IBM System Storage SAN Volume
Controller 2145 Troubleshooting Guide
to determine how to solve this problem or contact the IBM support
center.
Replacing the SAN Volume Controller 2145-8G4 service controller
Use the following information to replace the SAN Volume Controller 2145-8G4 service controller.
To replace the service controller, perform the following steps:
1.
Gently push the service controller (shown in Figure 90) into the frame until the rear connectors are
fully seated and the service controller front metal work is up to the frame.
2.
Slide the SAN Volume Controller 2145-8G4 back into the rack and check that all cables are still firmly
in place.
3.
Connect the power cable to the node and replace the cable-retention bracket. See “Replacing the
cable-retention bracket” on page 34.
Note:
The worldwide port names (WWPNs) of the fibre-channel ports are derived from the
worldwide node name (WWNN) of the service controller. If you do not perform step 4, you might
have to re-zone the fibre-channel switches if the switch zoning uses WWPN. You must restart the host
systems before they are able to access disks through this node.
4.
If you replaced the service controller as part of concurrent maintenance, you must rewrite the WWNN
on the new service controller. If you do not, and the fibre-channel switch zoning uses WWPNs, you
svc00246
Figure 90. SAN Volume Controller 2145-8G4 service controller
Chapter 2. Removing and replacing parts
89
Summary of Contents for SAN Volume Controller
Page 2: ......
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Page 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Page 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 333: ......
Page 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...