Before you begin
Before completing the steps below, verify with your database administrator that
the following conditions are not the cause of the problem:
v
The database manager has not been started on the database server.
v
The database manager was stopped.
v
The database agent was forced off by the system administrator.
v
The database manager has already allocated the maximum number of agents.
v
The database agent was terminated due to an abnormal termination of a key
database manager process.
If the problem is not due to any of the above, it is most likely that the application
is using multiple contexts with the local protocol. In this case, the number of
connections is limited by the number of shared memory segments to which a
single process can be attached. For example, on AIX, the limit is ten shared
memory segments per process.
Procedure
1.
On the computer with the database that you want to connect to, configure the
database manager to use TCP/IP on AIX.
2.
On the server system, log in as the DB2 instance owner.
3.
Set DB2COMM to TPC/IP, for example:
db2set DB2COMM=tcpip
4.
Edit the
/etc/services
file to include both a DB2 connection service port and a
DB2 interrupt connection if they do not already exist, such as,
db2cDB2 50000/tcp # DB2 connection service port
db2iDB2 50001/tcp # DB2 interrupt connection
# service port
5.
Update the database manager configuration, such as, db2 update dbm cfg
using svcename db2cDB2. The argument after svcename must match the name
of the DB2 connection port service that you placed in
/etc/services
.
6.
Start and stop DB2:
% db2stop
% db2start
What to do next
Restart the portal client.
A monitoring process fails to start on Linux or UNIX after changing a
.profile for root
IBM Tivoli Monitoring processes such as the monitoring server, portal server,
warehouse proxy agent, summarization and pruning agent, and other agents are
all started while you are logged on as a user ID on Linux and UNIX systems.
For many shell environments, the user ID has a
.profile
file that is run during the
initial processing to ensure a consistent working environment and must satisfy
certain requirements.
The
.profile
must satisfy these requirements:
Chapter 6. Connectivity troubleshooting
123
Summary of Contents for E027SLL-H - Tivoli Monitoring - PC
Page 1: ...IBM Tivoli Monitoring Version 6 2 3 FP1 Troubleshooting Guide GC32 9458 05...
Page 2: ......
Page 3: ...IBM Tivoli Monitoring Version 6 2 3 FP1 Troubleshooting Guide GC32 9458 05...
Page 14: ...xii IBM Tivoli Monitoring Troubleshooting Guide...
Page 16: ...xiv IBM Tivoli Monitoring Troubleshooting Guide...
Page 18: ...xvi IBM Tivoli Monitoring Troubleshooting Guide...
Page 22: ...4 IBM Tivoli Monitoring Troubleshooting Guide...
Page 82: ...64 IBM Tivoli Monitoring Troubleshooting Guide...
Page 144: ...126 IBM Tivoli Monitoring Troubleshooting Guide...
Page 164: ...146 IBM Tivoli Monitoring Troubleshooting Guide...
Page 188: ...170 IBM Tivoli Monitoring Troubleshooting Guide...
Page 240: ...222 IBM Tivoli Monitoring Troubleshooting Guide...
Page 262: ...244 IBM Tivoli Monitoring Troubleshooting Guide...
Page 274: ...256 IBM Tivoli Monitoring Troubleshooting Guide...
Page 276: ...258 IBM Tivoli Monitoring Troubleshooting Guide...
Page 284: ...266 IBM Tivoli Monitoring Troubleshooting Guide...
Page 288: ...270 IBM Tivoli Monitoring Troubleshooting Guide...
Page 302: ...284 IBM Tivoli Monitoring Troubleshooting Guide...
Page 308: ...290 IBM Tivoli Monitoring Troubleshooting Guide...
Page 309: ......
Page 310: ...Printed in USA GC32 9458 05...