15.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
go
to
“Installing
the
server
bezel
and
left-side
cover
(tower
model)”
on
page
100
or
“Installing
the
server
bezel
and
top
cover
(rack
configuration)”
on
page
103.
Working
with
the
3-Pack
Ultra320
Hot-Swap
Expansion
option
Your
server
contains
hardware
that
enables
you
to
replace
a
failed
hard
disk
drive
without
turning
off
the
server.
Therefore,
you
have
the
advantage
of
continuing
to
operate
your
system
while
a
hard
disk
drive
is
removed
or
installed.
These
drives
are
known
as
hot-swap
drives.
The
hot-swap
drives
are
attached
to
a
hot-swap
hard
disk
drive
backplane
.
The
backplane
is
a
printed
circuit
board
behind
the
drive
bays.
For
more
information
about
drive
bays
and
drive
installation,
see
“Installing
internal
drives”
on
page
74.
The
low
voltage
differential
(LVD)
SCSI
hot-swap
hard
disk
drive
backplane
supports
a
maximum
of
six
slim-high,
hot-swap
hard
disk
drives.
If
you
install
the
3-Pack
Ultra320
Hot-Swap
Expansion
option,
you
can
attach
up
to
three
additional
drives.
All
of
these
drives
must
be
LVD
hard
disk
drives
that
operate
at
320
MB
per
second
or
lower.
The
optional
3-Pack
Ultra320
Hot-Swap
Expansion
Kit
contains
a
hot-swap
hard
disk
drive
backplane
that
you
install
adjacent
to
the
standard
hot-swap
hard
disk
drive
backplane.
It
also
includes
the
SCSI
cable
you
need
to
install
the
option.
Your
server
supports
a
maximum
of
two
hot-swap
drive
backplanes.
Note:
All
drives
being
used
in
the
server
should
have
the
same
throughput
speed
rating:
mixing
speed
ratings
might
cause
all
drives
to
operate
at
the
lower
throughput
speed.
Do
the
following
to
configure
the
channels
on
the
two
SCSI
backplanes:
v
You
can
configure
each
SCSI
channel
(bus)
independently.
This
is
the
typical
backplane
configuration.
In
this
configuration:
–
The
hard
disk
drives
that
are
connected
to
the
standard
backplane
are
attached
to
channel
A.
–
The
hard
disk
drives
that
are
connected
to
the
3-Pack
Ultra320
Hot-Swap
Expansion
option
backplane
are
attached
to
channel
B.
Notes:
1.
The
standard
LVD
SCSI
backplane
is
also
known
as
the
SCSI
backplane
or
the
hot-swap
hard
disk
drive
backplane.
2.
The
SCSI
backplane
that
comes
with
the
3-Pack
Ultra320
Hot-Swap
Expansion
Kit
is
also
known
as
the
3-Pack
backplane.
3.
Table
8
on
page
112
lists
the
SCSI
identifiers
(IDs)
for
the
standard
LVD
SCSI
backplane
and
hard
disk
drives.
Table
9
on
page
112
lists
the
SCSI
IDs
for
the
3-Pack
backplane
and
hard
disk
drives.
4.
Cable
identifiers
are
printed
on
the
cables
that
come
with
your
server
and
options.
Use
these
identifiers
to
connect
the
cables
to
the
correct
connectors.
For
example,
the
hard
disk
drive
cables
are
labeled
“HDD
option.”
5.
For
information
about
other
options
and
using
the
3-Pack
Ultra320
Hot-Swap
Expansion
option,
see
the
documentation
that
comes
with
the
option
kit.
6.
For
additional
information
about
cabling,
see
“Cabling
example
for
a
ServeRAID
controller”
on
page
66
and
“Cabling
the
server”
on
page
106.
7.
The
SCSI
cables
that
come
with
your
server
can
only
be
used
with
the
integrated
SCSI
controller
with
RAID
capabilities.
If
a
RAID
controller
other
than
the
ServeRAID-5i
is
installed,
you
must
use
SCSI
cables
that
are
compatible
70
xSeries
235
Type
8671:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for 8671 - Eserver xSeries 235
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 24: ...14 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 38: ...28 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 54: ...44 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 138: ...128 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Related service information 179...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 191: ...Appendix B Related service information 181...
Page 192: ...182 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 193: ...Appendix B Related service information 183...
Page 194: ...184 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 195: ...Appendix B Related service information 185...
Page 205: ...Appendix B Related service information 195...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 207: ...Appendix B Related service information 197...
Page 208: ...198 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 209: ...Appendix B Related service information 199...
Page 210: ...200 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 214: ...204 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 220: ...210 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 221: ......
Page 222: ...Part Number 24P2965 1P P N 24P2965...