Notes:
1.
This
cabling
example
does
not
apply
to
the
ServeRAID-5i
controller,
which
uses
the
integrated
SCSI
controller
with
RAID
capabilities
on
the
system
board.
2.
An
optional
ServeRAID-5i
controller
can
be
installed
only
in
PCI-X
slot
4.
Slot
4
is
the
only
PCI-X
slot
that
supports
the
ServeRAID-5i
controller
requirements.
3.
Connections
made
to
external
SCSI
devices
will
be
asynchronous.
If
you
are
connecting
the
adapter
to
any
internal
SCSI
backplane
or
device,
you
will
need
to
purchase
additional
SCSI
cables.
Contact
your
IBM
marketing
representative
or
reseller
for
additional
information
about
the
number
and
types
of
cables
that
your
server
configuration
requires.
Your
server
comes
with
one
SCSI
cable
that
can
only
be
used
with
the
integrated
SCSI
controller
with
RAID
capabilities
that
is
on
the
system
board.
One
end
of
this
SCSI
cable
is
attached
to
the
connector
on
the
SCSI
backplane,
and
the
other
end
is
attached
to
the
SCSI
channel
A
connector
on
the
system
board.
The
SCSI
channel
B
connector
on
the
system
board
is
available
for
use,
but
the
server
does
not
come
with
a
cable
attached
to
it.
The
following
procedure
describes
the
cable
routing
that
is
necessary
when
you
install
a
ServeRAID
controller
other
than
ServeRAID-5i.
Notes:
1.
See
the
documentation
that
comes
with
your
adapter
for
any
cabling
instructions.
2.
Cable
identifiers
are
printed
on
the
cables
that
come
with
your
server
and
options.
Use
these
identifiers
to
connect
the
cables
to
the
correct
connectors.
For
example,
the
hard
disk
drive
cables
are
labeled
“HDD
option.”
Complete
the
following
steps
to
cable
the
ServeRAID
controller:
1.
Determine
the
number
of
SCSI
channels
that
you
want
to
use
on
the
ServeRAID
controller.
2.
Review
the
information
in
“Installation
guidelines”
on
page
45,
“Handling
static-sensitive
devices”
on
page
46,
and
“Safety
information”
on
page
169.
3.
Turn
off
the
server
and
disconnect
all
power
cords
and
external
cables
(“Turning
off
the
server”
on
page
9);
then,
remove
the
server
cover
(see
“Removing
the
server
left-side
cover
and
bezel
(tower
model)”
on
page
55
or
“Removing
the
server
top
cover
and
bezel
(rack
configuration)”
on
page
57).
4.
Lift
the
adapter-retention
clip
on
top
of
the
adapter-support
bracket;
then,
remove
the
full-length
adapters.
5.
Lift
and
remove
the
plastic
dividers
from
PCI-X
slots
5
and
6
by
lifting
the
ends
of
the
dividers
out
of
the
adapter
support
bracket
and
tilting
the
dividers
up
out
of
the
server.
6.
Disconnect
internal
cables
as
necessary,
remove
the
air-baffle
assembly,
and
remove
the
adapter-support
bracket
from
the
server.
For
complete
details,
see
“Removing
and
installing
the
adapter-support
bracket”
on
page
58.
Note:
You
must
remove
the
air-baffle
assembly
whenever
you
remove
the
adapter-support
bracket.
7.
Disconnect
the
internal
SCSI
cable
from
SCSI
connector
A
(J44)
or
B
(J51)
on
the
system
board.
See
“System-board
internal
cable
connectors”
on
page
49
for
the
location
of
the
SCSI
connectors.
Chapter
4.
Customer
replaceable
units
67
Summary of Contents for 8671 - Eserver xSeries 235
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 24: ...14 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 38: ...28 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 54: ...44 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 138: ...128 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Related service information 179...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 191: ...Appendix B Related service information 181...
Page 192: ...182 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 193: ...Appendix B Related service information 183...
Page 194: ...184 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 195: ...Appendix B Related service information 185...
Page 205: ...Appendix B Related service information 195...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 207: ...Appendix B Related service information 197...
Page 208: ...198 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 209: ...Appendix B Related service information 199...
Page 210: ...200 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 214: ...204 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 220: ...210 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 221: ......
Page 222: ...Part Number 24P2965 1P P N 24P2965...