v
Locate
the
documentation
that
comes
with
the
adapter
and
follow
those
instructions
in
addition
to
the
instructions
in
this
chapter.
If
you
need
to
change
the
switch
or
jumper
settings
on
your
adapter,
follow
the
instructions
that
come
with
the
adapter.
v
You
can
install
full-length
adapters
and
non-hot-plug
adapters
in
any
expansion
slot.
v
The
32-bit
PCI
slot
supports
5.0
V
signaling
PCI
adapters;
it
does
not
support
3.3
V
signaling
adapters.
v
The
64-bit
PCI-X
slots
2
through
6
support
3.3
V
signaling
PCI
or
PCI-X
adapters;
they
do
not
support
5.0
V
signaling
adapters.
v
The
PCI
bus
configuration
is:
–
Non-hot-plug,
32-bit
PCI
slot
1
is
on
PCI
bus
A,
33
MHz
–
Non-hot-plug,
64-bit
PCI-X
slots
2
and
3,
and
the
integrated
Ethernet
controller,
are
on
PCI
bus
B,
100
MHz
(independent
of
slot
4)
–
Non-hot-plug,
64-bit
PCI-X
slot
4
and
the
integrated
SCSI
controller
with
RAID
capabilities
are
on
PCI
bus
B,
100
MHz
(independent
of
slots
2
and
3)
–
Hot-plug,
64-bit
PCI-X
slot
5
is
on
PCI
bus
C,
133
MHz
(independent
of
slot
6)
–
Hot-plug,
64-bit
PCI-X
slot
6
is
on
PCI
bus
C,
133
MHz
(independent
of
slot
5)
Notes:
1.
PCI
bus
A
is
often
referred
to
as
bus
0;
PCI
bus
B
is
often
referred
to
as
bus
1
and
bus
2;
and
PCI
bus
C
is
often
referred
to
as
bus
3
and
bus
5.
However,
the
bus
numbers
vary
according
to
the
adapters
that
are
installed.
2.
If
an
optional
ServeRAID-5i
controller
is
installed,
it
overrides
the
standard
functionality
of
the
integrated
SCSI
controller
with
RAID
capabilities
and
forces
PCI-X
slot
4
to
66
MHz.
The
ServeRAID-5i
controller
must
be
installed
in
slot
4
using
the
3-U
bracket
that
comes
with
the
controller.
However,
if
a
ServeRAID-5i
controller
is
installed
and
later
removed,
you
must
re-enable
the
on-board
SCSI
controller
in
using
the
Configuration/Setup
Utility
program
(see
“Starting
the
Configuration/Setup
Utility
program”
on
page
15).
3.
The
integrated
SCSI
controller
with
RAID
capabilities
is
on
PCI
bus
B.
v
The
optional
IBM
Remote
Supervisor
Adapter
must
be
installed
in
PCI
slot
1
only.
Use
the
ribbon
cable
that
comes
with
the
adapter
to
connect
the
adapter
to
the
Remote
Supervisor
Adapter
connector
(J27)
on
the
system
board.
v
The
system
scans
PCI
and
PCI-X
slots
1
through
6
to
assign
system
resources.
The
system
then
starts
(boots)
the
system
devices
in
the
following
order,
if
you
have
not
changed
the
default
boot
precedence:
integrated
SCSI
controller
with
RAID
capabilities
(or
optional
ServeRAID-5i
controller),
integrated
Ethernet
controller,
and
then
PCI
and
PCI-X
slots
1
through
6.
Note:
To
change
the
boot
precedence
for
PCI
and
PCI-X
devices,
start
the
Configuration/Setup
Utility
program
and
select
Start
Options
from
the
main
menu
(see
“Starting
the
Configuration/Setup
Utility
program”
on
page
15).
v
The
Active
PCI-X
slots
contain:
–
Power-on
LEDs
–
Internal
attention
LEDs
–
External
attention
LEDs
Chapter
4.
Customer
replaceable
units
61
Summary of Contents for 8671 - Eserver xSeries 235
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 6: ...iv xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 24: ...14 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 38: ...28 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 54: ...44 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 138: ...128 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Related service information 179...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 191: ...Appendix B Related service information 181...
Page 192: ...182 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 193: ...Appendix B Related service information 183...
Page 194: ...184 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 195: ...Appendix B Related service information 185...
Page 205: ...Appendix B Related service information 195...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 207: ...Appendix B Related service information 197...
Page 208: ...198 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 209: ...Appendix B Related service information 199...
Page 210: ...200 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 214: ...204 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 220: ...210 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 221: ......
Page 222: ...Part Number 24P2965 1P P N 24P2965...