N700E INSTRUCTION MANUAL
5.4
Using Intelligent output terminals
Run Signal [RUN]
When the [RUN] signal is selected as an intelligent output terminal, the inverter
terminal when it is in the Run Mode.
The output logicis active low, and is the
Option
Code
Terminal
Symbol
Function Name
0
RUN
Run signal
Valid for inputs:
C13,C14,C15, C16, C17
Required setting
0
Notes:
•The inverter outputs the [RUN] signal whenever
the inverter output exceeds the startfrequency.
The start frequency is the initial inverter output
frequency when itturns on.
•Output terminal RN0-RN1 is a relay
In case of contact b, setup C16.
•Output terminal RN1-RN2 is a relay
In case of contact b, setup C17.
5-24
output terminals
When the [RUN] signal is selected as an intelligent output terminal, the inverter outputs a signal on that
terminal when it is in the Run Mode.
The output logicis active low, and is the relay type (a,b contact output)
Function Name
Input
State
Description
ON
when inverter is in Run Mode
OFF
when inverter Stop Mode
, C16, C17
•The inverter outputs the [RUN] signal whenever
tartfrequency.
The start frequency is the initial inverter output
relay contact a.
relay contact a.
outputs a signal on that
Description