N700E INSTRUCTION MANUAL
5-20
UP/DOWN Function [UP,DOWN]
• The Inverter output frequency can be changed with the UP and DOWN intelligent input terminals.
• Assign 18 (UP) and 19(DN)to two of the intelligent input terminals 1~6
•This function will not operate when the external analog frequency command or the jogging operation is used.
• Acceleration time operates according to F02, F03 when UP/DOWN terminal is ON.
Option
Code
Terminal
Symbol
Function Name
Input
State
Description
18
UP
UP Function
ON
Accelerating motor from present frequency.
(Output frequency increases.)
OFF
Motor output acts normally.
19
DOWN
DOWN
Function
ON
Decelerating motor from present frequency.
(Output frequency decreases.)
OFF
Motor output acts normally.
Valid for inputs:
C01,C02,C03,C04,C05,C06
Example:
Required setting
A02=01 or 02
Notes:
•
Be sure to set the run source setting
A02=01 or 02.
O peration com m and
(FW /RV)
U P
D O W N
O utput frequency
Inverter doesn’t accelerate
and decelerate, if U P,
D O W N term inal is turned
O N sim ultaneously.