Status screen
By default the status screen shows system status information.
Torch started –
This icon shows that the torch has received a start signal and has
started a pilot arc.
Torch is transferring –
This icon shows that the plasma arc transferred to the
workpiece and the torch is cutting or gouging.
System process –
This icon shows the maximum output current (A) of the
Hypertherm cartridge.
If there are no cartridge communications with the plasma power supply, this icon
does not show on the status screen.
Current setting (amperage) –
This is the current at which the plasma power supply
will cut or gouge, in amperage.
Use either the adjustment knob on the plasma power supply or the
amperage-adjustment control on the hand torch to change the output current.
Installing a Hypertherm cartridge of a different amperage also changes the
current setting.
Non-default configuration –
This icon shows that at least one default system setting
has been changed.
Remote control –
This icon shows that a CNC or other controller is controlling the
plasma power supply. The front panel controls are disabled during remote mode
operation. But fault codes and fault icons still show as they would otherwise,
and you can go to the menu screens to see information about the plasma power
supply, torch, and cartridge.
Cartridge data –
These fields show the total number of pilot arc starts (
STA
) and the
cumulative plasma arc transfer time (
XT
) for the life of the Hypertherm cartridge
that is installed on the torch. These fields do not show by default. Refer to
.
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...