Install and Set Up the Plasma Power Supply
2
24
810470
Operator Manual
Powermax65/85/105 SYNC
Hypertherm plasma power supply ratings
Powermax65 SYNC
Rated open-circuit voltage (U
0
)
CSA, 1-phase, 3-phase 296 VDC CSA
CE/CCC, 3-phase 270 VDC CE/CCC
Output characteristic
*
Drooping
Rated output current (I
2
)
20 A – 65 A
Rated output voltage (U
2
)
139 VDC
Duty cycle at 40°C (104°F)
**
CSA 50% at 65 A, 230 V – 600 V, 1-/3-phase
40% at 65 A, 200 V – 208 V, 1-/3-phase
100% at 46 A, 230 V – 600 V, 1-/3-phase
CE/CCC 50% at 65 A, 380 V/400 V, 3-phase
100% at 46 A, 380 V/400 V, 3-phase
Operating temperature
-10°C to 40°C (14°F to 104°F)
Storage temperature
-25°C to 55°C (-13°F to 131°F)
Power factor
200 V – 480 V CSA, 1-phase 0.99 – 0.97
200 V – 600 V CSA, 3-phase 0.94 – 0.73
380 V CCC/400 V CE, 3-phase 0.94
Idle state power consumption (CE systems)
28 W
Power source efficiency at rated maximum
output power (CE systems)
91.2%
R
sce
– Short Circuit Ratio (CE/CCC systems only)
U
1
– Volts AC rms, 3-phase 400 VAC
R
sce
296.4
EMC emissions classification CISPR 11 (CE/CCC systems only)
***
Class A
Input voltage (U
1
) / Input current (I
1
) at rated output (U
2 MAX
I
2 MAX
)
(Refer to
)
CSA, 1-phase, 50 Hz/60 Hz
CSA, 3-phase, 50 Hz/60 Hz
CE/CCC
†, ††
, 3-phase, 50 Hz/60 Hz
200 V:
208 V:
240 V:
480 V:
52 A
50 A
44 A
22 A
200 V:
208 V:
240 V:
480 V:
600 V:
32 A
31 A
27 A
13 A
13 A
380 V:
400 V:
15.5 A
15 A
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...