Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC
Operator Manual
810470
55
3.
Connect the gas hose to the gas inlet fitting. Refer to
Inlet gas pressure requirements (while gas
Gas supply source
1
2
3
Hypertherm recommends that air compressors supply air that meets the following requirements of
ISO Standard 8573-1:2010 Class 1.4.2
*
:
Maximum particle count in 1.0 m
3
:
• 20,000 at 0.1 microns – 0.5 microns
• 400 at 0.5 microns – 1.0 microns
• 10 at 1.0 microns – 5.0 microns
Maximum water vapor pressure dewpoint: 3°C (37°F)**
Maximum oil concentration: 0.1 mg/m
3
(for aerosol, liquid, and vapor)
*
Important:
Any air compressors that supply air to the cutting system must remove oil prior to air delivery.
** Speak to your air compressor manufacturer if you operate the cutting system in temperatures colder than 3°C (37°F)
or if you are unsure that the air compressor can comply with the ISO standard for air quality.
NOTICE
DIRTY, OILY AIR CAN CAUSE DAMAGE TO THE AIR FILTER BOWL
Synthetic lubricants containing esters that are used in some air compressors can cause damage to the
polycarbonates in the air filter bowl. Add additional gas filtration if necessary.
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...