Complete Regular Maintenance Tasks
7
Powermax65/85/105 SYNC
Operator Manual
810470
167
Every use
Plasma power supply
Torch
Examine the indicator LEDs and correct any fault conditions.
Refer to
Examine the cartridge for correct installation and
for wear. Refer to
Signs that a cartridge is near
To prevent overheating, do the following:
• Examine the work lead connector to make sure that it is
fully connected to the plasma power supply and is not
loose. Make sure that you turn the connector clockwise
approximately 1/4 turn until the connector is fully engaged
and locked in position.
• Do a check of the plug on the work lead. When a plug is
replaced, damage to the wire inside the plug can occur. If
the plug on the work lead has been replaced, look for
damage.
1
3
2