Troubleshoot Common Problems
6
Powermax65/85/105 SYNC
Operator Manual
810470
141
0-50-2
none
Yellow
The torch-lock switch is set to
the green “ready to fire” (
)
position, but the torch is not
prepared to fire.
This fault code identifies a condition in which an
additional step is necessary
for hand torches
before the hand torch will fire a plasma arc.
• When you move the torch-lock switch to the
green “ready to fire” (
) position, the fault
code changes from 0-50-1 to 0-50-2, and
the
icon goes off.
•
Hand torch:
Fire the torch 1 time to get the
warning puffs of air. The 0-50-2 fault code
goes off, and the LED on the hand torch
changes from yellow to green. The torch is
now prepared to fire a plasma arc.
•
Machine torch:
The 0-50-2 fault code
shows for approximately 1 second and then
goes off. Fire the torch to get a plasma arc.
There are no warning puffs of air. If the
0-50-2 fault code does not go off, send a
STOP signal from the CNC to remove the
fault.
•
Mini machine torch:
This fault code is not
applicable to the mini machine torch.
0-51-0
Yellow
Yellow
The plasma power supply
was receiving a signal to start
cutting at the same time that
the power switch was set to
ON (
I
).
With a machine torch, this
condition is sometimes
referred to as a “stuck start.”
This fault code stops the system from operating.
Do the following. A quick restart is necessary.
•
Hand torch:
The torch trigger was being
held in the “fire” position when the power
switch on the plasma power supply was set
to ON (
I
). Release the trigger and do a
quick restart of the plasma power supply.
•
Machine torch:
The plasma power supply
was receiving a Start signal when the power
switch was set to ON (
I
). Set the start
signal to off, and do a quick restart of the
plasma power supply.
0-52-0
Yellow
Yellow
The torch is not connected.
This fault code stops the system from operating.
Do the following. A quick restart is necessary.
• Make sure that the torch lead is correctly
connected to the FastConnect receptacle
on the front of the plasma power supply. Do
a quick restart.
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...