Troubleshoot Common Problems
6
Powermax65/85/105 SYNC
Operator Manual
810470
135
0-14-0
Yellow
Flashes
yellow
There is a problem with the
cartridge installation.
This fault shows when you install a cartridge,
and it cannot send data to the plasma power
supply. This fault code stops the system from
operating.
Do one of the following:
• Set the torch-lock switch to the yellow
lock (
X
) position and then back to the green
“ready to fire” (
) position.
• Do a quick restart.
• Install the cartridge again.
If you get frequent 0-14-0 faults, electrical noise
can cause a bad data connection. For example,
high frequency electrical noise from TIG welders
can cause interference. Keep electrical noise in
the work area as low as possible.
If you do not remove this fault code, the system
automatically adjusts the following settings to
prevent possible damage to the workpiece and
cartridge:
• It sets the output current to 45 A.
• It sets the operating mode to Cut mode.
• It sets the output gas pressure to cut
pressure.
If necessary, you can manually change these
settings to cut without a data connection.
0-14-1
Flashes
yellow
The cartridge is not
recognized.
This fault shows when a cartridge cannot send
data to the plasma power supply for some
reason. This fault code does not stop the system
from operating.
• When this fault occurs, you can continue to
cut or gouge, but
you must set the output
current (A) and the operating mode
manually
. Also, the system cannot collect
data about the Hypertherm cartridge.
• Lightly blow air into the cartridge to remove
all dust or other contamination. Install the
cartridge again.
• Make sure that the
green ring inside the
cartridge is not broken.
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...