Troubleshoot Common Problems
6
Powermax65/85/105 SYNC
Operator Manual
810470
143
0-61-0
Yellow
Yellow
An AC input is not stable.
Shut down the system.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
• The current from the incoming power line is
unstable. Stop power to the system and
correct the line resonance problem before
continuing.
• If possible, connect the system to a different
AC power source.
• Make sure that the plasma power supply is
not being used on a phase converter.
• If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to
power-related problems with generators
0-98-0
Yellow
Yellow
An internal communication
failure occurred between the
LCD/control PCB and the
DSP PCB.
This fault code can stop the system from
operating in some conditions. You can continue
to cut, but the controls on the front panel are not
available. Hypertherm recommends that you do
the following.
• Set the power switch on the plasma power
supply to OFF (
O
). Wait until all the
amperage LEDs on the SmartSYNC hand
torch go off. (Or, wait approximately
1 minute.) Set the power switch to ON (
I
).
If the problem continues, a qualified service
technician must open the plasma power supply
and examine the ribbon cable between the
LCD/control PCB and the DSP PCB.
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...