Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC
Operator Manual
810470
27
Gas type
Air
Nitrogen
F5
†††
Gas quality
Clean, dry, oil-free per
ISO 8573-1 Class 1.4.2
.
99.95% pure
99.98% pure
(F5 = 95% nitrogen [N
2
],
5% hydrogen [H
2
])
Recommended gas inlet flow rates
Cutting 210 slpm (450 scfh, 7.5 scfm) at a minimum 5.9 bar (85 psi)
Maximum Removal gouging 210 slpm (450 scfh, 7.5 scfm) at a minimum 4.8 bar (70 psi)
Maximum Control gouging 210 slpm (450 scfh, 7.5 scfm) at a minimum 4.8 bar (70 psi)
* Defined as a plot of output voltage versus output current.
** Refer to the data plate on the rear of the plasma power supply for more information on duty cycle and for
IEC ratings.
*** WARNING: This Class A equipment is not intended for use in residential locations where the public low voltage
supply system supplies the electrical power. There can be difficulties in delivering electromagnetic compatibility in
those locations, because of conducted as well as radiated disturbances.
†
Equipment complies with IEC 61000-3-12 if the short-circuit power S
sc
is greater than or equal to 4,353 KVA at
the interface point between the operator’s supply and the public system. It is the responsibility of the installer or
operator of the equipment to make sure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power S
sc
greater than or equal to 4,353 KVA.
††
Equipment complies with IEC 61000-3-11 if the supply impedance, Zmax, is 0.201 or less. It is the responsibility of
the installer or operator of the equipment to make sure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a impedance of 0.201 or less.
†††
F5 recommended only for cutting stainless steel. Refer to
Cut stainless steel with F5
in the
Powermax65/85/105 SYNC Mechanized Cutting Guide
(810480).
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...