Troubleshoot Common Problems
6
148
810470
Operator Manual
Powermax65/85/105 SYNC
5.
Use the gas test screen to compare the plasma power supply’s actual output gas pressure
to
the gas pressure that the system sets
to align with the type of cartridge and torch installed.
For the system to operate optimally, the output gas pressure
must not be lower than the
system’s target gas pressure
by more than the following quantities:
Cut mode at 105 A: -0.3 bar (-5 psi)
Cut mode at 85 A: -0.3 bar (-4 psi)
Cut mode at 65 A: -0.2 bar (-3 psi)
Cut mode at 45 A: -0.1 bar (-2 psi)
Gouge mode at 45 A – 105 A: -0.1 bar (-2 psi)
6.
Push the operating mode button to stop the gas test and go back to the status screen. Gas
stops flowing from the torch.
7.
If the output gas pressure was too low in step 5, examine the inlet pressure from the gas supply
source. For inlet pressure requirements, refer to
Do a gas test in manual gas pressure mode
If the plasma power supply is in manual gas pressure mode when you start a gas test, the gas test
screen shows the plasma power supply’s actual output gas pressure
and the manual gas
pressure setting
.
You can turn the adjustment knob to change the manual gas pressure setting during a gas test.
You can push
during a gas test to change from manual gas pressure mode to automatic gas
pressure mode or from automatic gas pressure mode to manual gas pressure mode.
1
2
1
2
1
2
1
2
1
2
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...