Troubleshoot Common Problems
6
120
810470
Operator Manual
Powermax65/85/105 SYNC
Examine the front panel controls
Is the fault LED on?
Does a fault code and fault icon show on the
s
tatus screen? Is the AC LED
flashing?
Refer to
.
Make sure that the operating mode is correct. For example, use Expanded Metal mode only when you
are cutting expanded metal. Refer to
Does the
s
tatus screen show the non-default configuration icon (at right) but not the
icon? Does the plasma power supply operate as expected? For example, does
the plasma power supply not change to the correct operating mode for the Hypertherm
cartridge that you installed when you are using a SmartSYNC torch and Hypertherm cartridge?
If so, set the plasma power supply back to factory default settings to see if that is a solution to the
problem. Push and hold
and
at the same time for approximately 2 seconds. Refer to
Examine the power cord*
Is the power cord plugged in? Or is it connected correctly to a line-disconnect switch or other power
source?
Is there any visible damage to the power cord? Are any wires exposed or frayed?
Examine the power cord wires in the power plug or line-disconnect box. Are any of the wires
shorted?
Is the power plug correct for the power cord? For example, do not install a 1-phase power
plug
on a
3-phase power
cord
Prepare the power cord and plug
Powermax65/85 SYNC CSA plasma power supplies:
If you are using the plasma power supply on
1-phase power, did you install a 1-phase power cord? Are the wires in the power cord and power
plug correct for 1-phase power? The plasma power supply comes with a 3-phase power cord. Refer
to
.
Powermax105 SYNC plasma power supplies cannot be used on 1-phase power.
Is the power cord ground wire connected to ground in the plasma power supply and in the power
plug or line-disconnect box?
Are the rest of the power cord wires connected correctly in the plasma power supply and in the
power plug or line-disconnect box? Refer to
.
Are the power cord wires fully tightened inside the plasma power supply and in the power plug or
line-disconnect box?
* Make sure that any changes to the plasma power supply or power cord are done by a licensed electrician.
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...