Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC
Operator Manual
810470
29
Power source efficiency at rated maximum
output power (CE systems)
230 V – 400 V CE
400 V CE
91.0%
91.9%
R
sce
– Short Circuit Ratio (CE/CCC systems only)
U
1
– Volts AC rms, 3-phase 230 V – 400 V
400 V
R
sce
235.4 176.9
EMC emissions classification CISPR 11 (CE/CCC systems only)
***
Class A
Input voltage (U
1
) / Input current (I
1
) at rated output (U
2 MAX
I
2 MAX
)
(Refer to
CSA, 3-phase, 50 Hz/60 Hz
CE
†,††
,
3-phase, 50 Hz/60 Hz
CE
††, †††
/CCC, 3-phase,
50 Hz/60 Hz
200 V:
208 V:
240 V:
480 V:
600 V:
58 A
56 A
49 A
25 A
22 A
230 V:
400 V:
50 A
29 A
380 V:
400 V:
30 A
28 A
Gas type
Air
Nitrogen
F5‡
Gas quality
Clean, dry, oil-free per
ISO 8573-1 Class 1.4.2
99.95% pure
99.98% pure
(F5 = 95% nitrogen [N
2
],
5% hydrogen [H
2
])
Recommended gas inlet flow rates
Cutting 260 slpm (550 scfh, 9.1 scfm) at a minimum 6.2 bar (90 psi)
Maximum Removal gouging 260 slpm (550 scfh, 9.1 scfm) at a minimum 4.8 bar (70 psi)
Maximum Control gouging 260 slpm (550 scfh, 9.1 scfm) at a minimum 4.8 bar (70 psi)
* Defined as a plot of output voltage versus output current.
** Refer to the data plate on the rear of the plasma power supply for more information on duty cycle and for
IEC ratings.
*** WARNING: This Class A equipment is not intended for use in residential locations where the public low voltage
supply system supplies the electrical power. There can be difficulties in delivering electromagnetic compatibility in
those locations, because of conducted as well as radiated disturbances.
†
Equipment complies with IEC 61000-3-12 if the short-circuit power S
sc
is greater than or equal to 4,730 KVA at
the interface point between the operator’s supply and the public system. It is the responsibility of the installer or
operator of the equipment to make sure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power S
sc
greater than or equal to 4,730 KVA.
††
This product complies with the technical requirements of IEC 61000-3-3 and is not subject to conditional
connection.
†††
Equipment complies with IEC 61000-3-12 if the short-circuit power S
sc
is greater than or equal to 2,114 KVA at
the interface point between the operator’s supply and the public system. It is the responsibility of the installer or
operator of the equipment to make sure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power S
sc
greater than or equal to 2,114 KVA.
‡ F5 recommended only for cutting stainless steel. Refer to
Cut stainless steel with F5
in the
Powermax65/85/105 SYNC Mechanized Cutting Guide
(810480).
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...