Install and Set Up the Plasma Power Supply
2
42
810470
Operator Manual
Powermax65/85/105 SYNC
The recommended fuse sizes let spikes in input current occur when you
stretch the plasma arc. Stretching the plasma arc is common in some
applications, such as gouging.
Powermax65 SYNC
CSA configurations (1-phase)
CSA configurations (3-phase
)
CE/CCC configurations (3-phase
)
Input voltage at 50 Hz/60 Hz*
200 V – 208 V 230 V – 240 V
480 V
Input current at rated output (65 A × 139 VDC = 9.0 kW)
52 A / 50 A
44 A
22 A
Input current during arc stretch
74 A
74 A
38 A
Fuse (time-delay)
80 A
80 A
40 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz*
200 V – 208 V 230 V – 240 V
400 V
480 V – 600 V
Input current at rated output
(65 A × 139 VDC = 9.0 kW)
32 A / 31 A
27 A
15 A
13 A
Input current during arc stretch
45 A
45 A
27 A
23 A
Fuse (time-delay)
50 A
50 A
30 A
25 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz*
380 V
400 V
Input current at rated output (65 A × 139 VDC = 9.0 kW)
15.5 A
15 A
Input current during arc stretch
27 A
27 A
Fuse (time-delay)
30 A
30 A
* All models have a voltage tolerance of +10% / -15%.
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...