![Hurco AB6 Installation Manual Download Page 157](http://html1.mh-extra.com/html/hurco/ab6/ab6_installation-manual_2187300157.webp)
Installation Manual
2-118
Revision E
Hurco
❑
16.
Route the console cable (harness) along the side walls of the press
brake to the console.
❑
17.
Connect the cable to the connector J3. (Note the correct alignment of
the connector key.)
❑
18.
Route the gauge cable(s) from the AB6 power cabinet along the side
walls of the press brake to the gauge(s).
❑
19.
Connect the gauge cables to the gauge(s). (Make sure that the cables
do not interfere with the gauge movement.)
❑
20.
Wire the incoming power to the IEC power plug. (Note the voltage
marked on the data plate.) Make sure to use a dedicated 3 wire
service. Ensure a single point ground.
❑
21.
Using the self-tapping screws and tie wraps, secure all cables to the
press brake.
❑
22.
Perform the system checkout:
a.
Check to make sure area is clear.
b.
Check for proper press brake operation.
c.
Turn on the external power source.
d.
Turn on the power switch located on the right side of the
AB6 power cabinet. The LEDs illuminate.
e.
For units configured for the Y-axis, press the Enter key
followed by the Ram On key to change the mode to Standby
Manual mode. (The Ram On LED will be off.)
f.
Press the Jog key.
g.
Press the Run key. The gauge(s) should calibrate.
h.
Jog the gauge(s) forward by pressing the
∨
key. Verify that
the gauge(s) moves.
i.
Press the
∧
key. Verify that the gauge(s) moves back.
❑
23.
Program and run a job. Refer to the “Programming and Operations”
manual for details.
❑
24.
Contact Hurco to schedule an installation date with a factory-trained
installer for the Y- axis.
Summary of Contents for AB6
Page 3: ...iv Revision E Hurco...
Page 5: ...vi Revision E Hurco...
Page 13: ...Installation Manual xiv Revision E Hurco...