Optional Retract Sensor
The retract sensor is an option for the AB6. It signals the gauge to retract
to its programmed retract dimension when the ram or bed reaches the
material’s pinching point position.
Note
A retract sensor is NOT used for downacting hydraulic systems
equipped with hydraulic ram control. The ram control measures the
ram position and signals the gauge to retract when programmed. The
following information does not pertain to these types of systems.
The retract sensor is mounted to the side wall of the press brake. When the
sensor closes, the LED on the sensor box switches off to indicate the
sensor’s activation. The magnet is mounted to the press brake’s ram or bed
(whichever moves). As the press brake moves, the magnet passes the
sensor which triggers the retract.
Locate these materials in the AB6 installation kit:
•
retract sensor box
•
adjustment bracket
•
two (2) “L” brackets
•
black magnet
•
mounting hardware
Warning
Improper retract sensor mounting may cause the gauge
to retract at an inappropriate time. Gauge may run at
high speed.
Keep clear of the gauge, gauge bar, and pinch points at
all times.
Please read all instructions pertaining to the installation
of the retract sensor prior to attempting installation.
Make sure that the retract sensor and magnet will not
interfere with the press brake during operation.