![Hurco AB6 Installation Manual Download Page 109](http://html1.mh-extra.com/html/hurco/ab6/ab6_installation-manual_2187300109.webp)
Installation Manual
2-70
Revision E
Hurco
2.
Install a cord-grip conduit fitting in the Guifil power box
adjacent to the connection points.
3.
Route the two-conductor cable through the fitting into the
power box and up to the connection points.
Caution
Do not route the cable adjacent to any electrical cables.
4.
Route the other end of the cable to the AB6 power cabinet.
Do not route this cable adjacent to any electrical cables.
5.
Remove the 7/8" (22.22 mm) diameter knock out for the 1/2"
conduit fitting at the bottom of the AB6 power cabinet.
6.
Route about 10" (254 mm) of the cable through the fitting
into the AB6 power cabinet.
7.
Strip back 2" (51 mm) of the outer insulation.
8.
Cut off the shield and dispose.
9.
Strip back 1/4" (6 mm) of insulation on each of the individual
wires.
10.
Locate the Main board mounted inside the AB6 power
cabinet on the left-hand side.
11.
Locate and remove the J8 connector in the lower portion of
the Main board.
12.
Remove the J8 connector.
13.
Using a small screwdriver, open position #1 (labeled
ADVANCE) and insert the clear wire.
14.
Open position #7 (labeled 24 COM) and insert the black
wire.
15.
Replace the J8 connector.
Important
The “Main Board and J8 Connector” sections earlier in this chapter
contain information about locating the connector and opening the
position on it.
Summary of Contents for AB6
Page 3: ...iv Revision E Hurco...
Page 5: ...vi Revision E Hurco...
Page 13: ...Installation Manual xiv Revision E Hurco...