Changing Incoming Power Connections
If the incoming power source differs from what appears on the AB6 power
cabinet’s Data Plate, make appropriate changes to the AB6 power cabinet.
Refer to the figures below and follow the steps as indicated.
1.
Locate the IEC Power Entry Module (shown below) on the
upper right-hand side of the AB6 power cabinet.
0
ON/OFF SWITCH
FUSE CLIP
POWER SOCKET
TAB
VOLTAGE SELECTION WINDOW
Figure 2-78. IEC Power Entry Module
2.
Remove the fuse clip by depressing the tab located next to it.
Inside the clip are two fuses and the Voltage Selector (see the
figure below).
FUSES
VOLTAGE SELECTOR
FUSE CLIP
Figure 2-79. Side View of Fuse Clip Showing Voltage Selector