14.
Route the two-conductor cable along the press brake’s frame
to the AB6 power cabinet.
Caution
Avoid routing this cable adjacent to any electrical cables.
15.
Route the cable through the fitting and into the AB6 power
cabinet.
16.
Remove excess cable leaving only 10" (254 mm) of cable
inside the cabinet.
17.
Strip back 5" (127 mm) of outer insulation, and remove the
shield.
18.
Strip back 1/4" (6 mm) of insulation on both ends from the
individual wires.
19.
Connect the wires to the relay socket COM and N.O.
connections. (Refer to the relay diagrams at the beginning of
this section: the Relay Socket diagram, terminals 5 and 3, and
the Relay Diagram.)
20.
Locate and remove the J8 connector in the center lower
portion of the Main board.
21.
Using a small screwdriver, open position #1 (labeled
ADVANCE) and insert one of the wires.
22.
Open position #7 (labeled 24 COM) and insert the remaining
wire.
23.
Replace the connector into J8.