Command Manual – System Management
Quidway S8500 Series Routing Switches
Chapter 4 System Maintenance Commands
Huawei Technologies Proprietary
4-36
Parameter
level
: level.
levelnum:
Information level value, ranging from 1 to 8.
emergencies
,
alerts
,
critical
,
debugging
,
errors
,
informational
,
notifications
,
warnings
are the names of the eight log severity levels. You can type the values or
names of the desired severity levels, which are equivalent, in commands. Table 4-5
gives the details.
Table 4-5
Severity levels defined in the information center
Severity
Value
Description
emergencies 1
Emergent
errors
alerts
2
Errors you must correct immediately
critical 3
Critical
errors
errors
4
Errors requiring your attention but not critical
warnings
5
Warning, an error may occur
notifications
6
Information requiring your attention
informational
7
General prompt information
debugging 8
Debugging
information
size
: Configures the size of buffer.
sizenum
: Size of buffer (number of messages which can be kept); ranging from 1 to
1024. By default, the size of the buffer is 256.
|: Filters the configuration information to be output by regular expression.
begin
: Begins with the line that matches the regular expression.
exclude
: Excludes lines that match the regular expression.
include
: Includes lines that match the regular expression.
text
: Defines the regular expression.