undo temperature-limit slot
View
User view
Parameter
slot
: Physical card number.
down-value
: Lower temperature limit, in the range 0 to 70 °C.
up-value
: Upper temperature limit, in the range 20 to 90 °C.
Description
Use the
temperature-limit
command to configure temperature limit.
Use the
undo
temperature-limit
command to restore temperature limit to default
value.
Example
# Set the lower and upper temperature limit of card 0.
<Quidway> temperature-limit 0 10 75
3.1.15 update l3plus
Syntax
update l3plus
slot
slot-no
filename
file-name
ftpserver
server-name
username
user-name
password
password
[
port
port-num
]
View
System view
Parameter
slot-no
: Slot for the service processing board to be updated.
file-name
: Name of upgrading file to be downloaded. The file suffix is .app.
server-name
: IP address or host name of FTP Server where the file to be updated
locates.
user-name
: User name for file transfer protocol (FTP) login.
password
: User password for FTP login.
port-num
: FTP port number, in the range 0 to 65,535. By default, it is 21.
Description
Use the
update l3plus
command to update service processing boards. After the
command is executed, the system logs into an FTP Server with the host name, user