Command Manual – System Management
Quidway S8500 Series Routing Switches
Chapter 4 System Maintenance Commands
Huawei Technologies Proprietary
4-13
Description
Use the
display clock version
command to query the version information of the clock
device.
Example
# Query version information of the clock device.
<Quidway> display clock version
Clock module version
Software version: v010
Hardware version: Rev.A
CPLD version: v009
Release date: 2002.02.26
4.2.11 display clock d/a
Syntax
display clock d/a
View
Any view
Parameter
None
Description
Use the
display clock d/a
command to query the D/A value of the clock device.
Example
# Query the D/A value of the clock device.
<Quidway> display clock d/a
DAC Voltage : 2048
4.2.12 display clock basephase
Syntax
display clock basephase
View
Any view