Command Manual – Security
Quidway S8500 Series Routing Switches
Chapter 2 AAA and RADIUS/HWTACACS Protocol
Configuration Commands
Huawei Technologies Proprietary
2-24
Description
Use the
data-flow-format
command to configure the unit of data flow that send to
RADIUS Server.
Use the
undo data-flow-format
command to restore the unit to the default setting.
By default, the data unit is byte and the data packet unit is one-packet.
Related command, see
display radius
.
Example
# Set the unit of data flow that send to RADIUS Server Huawei is kilo-byte and the data
packet unit is kilo-packet.
[Quidway-radius-huawei] data-flow-format data kilo-byte packet kilo-packet
2.2.3 debugging radius
Syntax
debugging radius
packet
undo debugging radius
packet
View
User view
Parameter
packet
: Enable packet debugging
Description
Use the
debugging radius
command to enable RADIUS packet debugging.
Use the
undo debugging radius
command to disable RADIUS packet debugging.
By default, RADIUS packet debugging is disabled.
Example:
# Enable RADIUS packet debugging.
<Quidway> debugging radius packet
2.2.4 display local-server
Syntax
display local-server
{
statistics
|
nas-ip
}
View
Any view