![Huawei Quidway S8500 Series Command Manual Download Page 1092](http://html.mh-extra.com/html/huawei/quidway-s8500-series/quidway-s8500-series_command-manual_1694791092.webp)
Command Manual – System Management
Quidway S8500 Series Routing Switches
Chapter 4 System Maintenance Commands
Huawei Technologies Proprietary
4-50
debugging
: Debugging information.
level
: Level.
severity
: Information level, do not output information below this level.
Table 4-10 gives detailed severity information:
Table 4-10
Severity levels defined in the information center
Severity
Value
Description
emergencies 1 Emergent
errors
alerts
2
Errors you must correct immediately
critical 3
Critical
errors
errors
4
Errors requiring your attention but not critical
warnings
5
Warning, an error may occur
notifications
6
Information requiring your attention
informational
7
General prompt information
debugging 8
Debugging
information
By default, the information level of each channel is as follows:
Table 4-11
Default information level of each channel
channel
Log information
level
Trap information
level
Debugging
information level
Console warning
debugging debugging
Terminal warning
debugging debugging
Log host
informational
debugging
debugging
Trapbuffer informational warning
debugging
Logbuffer warning
debugging debugging
SNMPagent debugging
warning
debugging
Logfile warning debugging
debugging
Channel7 debugging debugging debugging
Channel8 debugging debugging debugging
Channel9 debugging debugging debugging
By default, the information switch state of each channel is shown in Table 4-12: