Table 2-13
Environmental specifications
Item
Specifications
Dimensions (H x
W x D)
175 mm (4U) x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)
Installation space
The server fits into a universal cabinet that complies with the IEC 297
standard:
l
Width: 19 in.
l
Depth: > 1000 mm (39.37 in.)
Guide rail installation requirements are as follows:
l
L-shaped guide rails: apply only to a Huawei cabinet.
l
Adjustable guide rails: apply to a cabinet where the distance
between the front and rear mounting bars is 543.5 mm to 848.5
mm (21.40 in. to 33.41 in.).
l
Holding rails: apply to a cabinet where the distance between the
front and rear mounting bars is 610 mm to 914 mm (24.02 in. to
35.98 in.).
PSU power rating
The PSUs support the following power ratings:
l
750 W AC PSU: 750 W (input voltage range: 100 V to 240 V AC
or 192 V to 288 V DC)
l
800 W DC PSU: 800 W (input voltage range:
–
36 V to
–
75 V
DC)
l
1200 W high-voltage direct current (HVDC) PSU: 1200 W (input
voltage range: 260 V to 400 V DC)
l
1200 W AC PSU:
–
750 W (input voltage: 100 V AC)
–
900 W (input voltage range: 110 V to 127 V AC)
–
1200 W (input voltage range: 200 V to 240 V AC)
–
1200 W (input voltage range: 192 V to 288 V DC)
Weight in full
configuration
l
With 36 hard disks: 57 kg (125.69 lb)
l
With 24 hard disks: 48 kg (105.84 lb)
Packaging materials: 15 kg (33.08 lb)
Rated input
voltage
l
750 W or1200 W AC PSUs: 100 V to 240 V AC
l
750 W or 1200 W AC PSUs (compatible with 240 V HVDC
PSUs): 192 V to 288 V DC
l
800 W DC PSUs:
–
36 V to
–
75 V DC
l
1200 W high-voltage direct current (HVDC) PSUs: 260 V to 400
V DC
NOTE
The recommended current specification for the external power circuit breaker
connected to the server is 32 A.