4.
Install the software on the server blade. The Quick Restore DVD is used for this purpose. See
“Recovering the X9720 Network Storage System” (page 125)
for more information.
5.
Set up fail over. For more information, see the HP StorageWorks X9000 File Serving Software
User Guide.
6.
Enable high availability (automated failover) by running the following command on server 1:
# ibrix_server –m
7.
Discover storage on the server blade:
ibrix_pv -a
8.
To enable health monitoring on the server blade, first unregister the vendor storage:
ibrix_vs -d -n <vendor storage name>
Next, re-register the vendor storage. In the command,
<sysName>
is, for example, x710.
The
<hostlist>
is a range inside square brackets, such as
X710s[2–4]
. If the first server
(
x710s1
in this example) is hosting the dedicated Management Server, do not include it in
the
<hostlist>
.
ibrix_vs -r -n <sysName> -t exds 172.16.1.1 -U exds -P <password>
-h <hostlist>
9.
If you made any other customizations to other servers, you may need to apply them to the
newly installed server.
80
Upgrading the X9720 Network Storage System hardware