![HP StorageWorks 6000 - Virtual Library System User Manual Download Page 66](http://html.mh-extra.com/html/hp/storageworks-6000-virtual-library-system/storageworks-6000-virtual-library-system_user-manual_165614066.webp)
To upgrade to higher capacity disks:
1.
Backup the current VLS virtual cartridges to tape. Use the tape copy feature from the backup
application.
2.
Ensure the MSA firmware is at 2.02 or later and the VLS software version is at 2.0.0 or later,
which are the required minimum versions to support the higher capacity disks. If necessary,
download and install the correct software and firmware before continuing.
3.
Purchase the required number of individual SATA drives from HP. All 12 drives in an array must
be of the same type. Do not mix drive types within an array.
4.
To upgrade to 750 GB disks, purchase and install one additional capacity license per 750 GB
disk. (750 GB disks require two licenses each, as opposed to 250 and 500 GB disks which re-
quire only one license each.)
5.
Power off the node. See “
Powering Off the System
” on page 130.
6.
Remove all disks from each array that is to be upgraded and replace them with higher capacity
disks.
7.
Power on the node. See “
Powering on the VLS6000–series System
” on page 125.
8.
Run a “Rebuild Storage Pools” operation from Command View VLS. See
Rebuilding the Storage
Pool
. This deletes the current RAID configuration and recreates it.
9.
Recreate previous virtual cartridges using Command View VLS. See
“
Creating Cartridges
” on page 166.
10.
Restore previous virtual cartridge data from the backup tapes to the virtual cartridges. Use the
tape copy feature from the backup application.
Removing Arrays
Removing an array from the system destroys all current virtual tapes in the system. Once a disk array
is added to the VLS, the only way it can be removed from the VLS storage pool is by powering off
the node, removing the array, powering on the node, then running Rebuild Storage Pool (see
Rebuilding
the Storage Pool
). This will delete the array from the configuration and reformat the remaining arrays
into working capacity.
In addition, if you add a used array to another system you must perform the steps listed in this section
then run Rebuild Storage Pool in order to add the capacity to your system. This destroys all current
virtual tapes in the system while it reformats all the arrays to reflect the new working capacity.
Managing Storage Pools
The VLS6000–series virtual tape library automatically creates one pool across all arrays on the library.
On the system page, select Storage Pools to view the pool information. When necessary, you can
also rebuild the pool from this screen.
Viewing the Storage Pool
To view the storage pool information:
1.
Open a Command View VLS session and log in as the administrator. See
“
Opening a Command View VLS Session from a Web Browser
” on page 135.
2.
Select
Storage Pools
in the navigation tree.
Storage Configuration
66
Summary of Contents for StorageWorks 6000 - Virtual Library System
Page 26: ...Introduction 26 ...
Page 70: ...Storage Configuration 70 ...
Page 116: ...Automigration Replication 116 ...
Page 132: ...Operation 132 ...
Page 140: ...User Interfaces 140 ...
Page 178: ...Management 178 ...
Page 256: ...Component Identification 256 ...
Page 300: ...Component Replacement 300 ...
Page 310: ...Support and Other Resources 310 ...
Page 326: ...Specifications 326 ...
Page 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Page 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Page 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Page 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Page 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Page 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Page 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Page 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Page 348: ...Glossary 348 ...
Page 358: ...358 ...