QuickFind Diagnostic Display LEDs
The QuickFind Diagnostic Display is located on the top of the access panel and displays the node
internal component and temperature status.
Action
Status
Description
Item
Be sure fan is installed and seated properly.
If fan is installed and seated properly, replace the fan.
Off = Normal
On = Attention
required
Fan
1
Processor pre-failure notification. Inspect the IML logs
and POST messages.
Processor might need to be replaced.
Off = Normal
On = Attention
required
Processor
2
Processor memory board power failure.
If problem persists, replace the processor or processor
memory board.
Off = Normal
On = Attention
required
Processor memory
board
3
PPM power failure. If problem persists, replace PPM.
If the PPM and the BRD LEDs are both on, there is a
configuration error.
Off = Normal
On = Attention
required
Processor power
module
4
HP StorageWorks
249
Summary of Contents for StorageWorks 6000 - Virtual Library System
Page 26: ...Introduction 26 ...
Page 70: ...Storage Configuration 70 ...
Page 116: ...Automigration Replication 116 ...
Page 132: ...Operation 132 ...
Page 140: ...User Interfaces 140 ...
Page 178: ...Management 178 ...
Page 256: ...Component Identification 256 ...
Page 300: ...Component Replacement 300 ...
Page 310: ...Support and Other Resources 310 ...
Page 326: ...Specifications 326 ...
Page 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Page 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Page 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Page 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Page 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Page 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Page 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Page 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Page 348: ...Glossary 348 ...
Page 358: ...358 ...