![HP StorageWorks 6000 - Virtual Library System User Manual Download Page 311](http://html.mh-extra.com/html/hp/storageworks-6000-virtual-library-system/storageworks-6000-virtual-library-system_user-manual_165614311.webp)
A Troubleshooting
This appendix describes some common issues you may encounter while configuring or using the VLS
including automigration/replication and deduplication issues.
VLS Common Issues
Solution
Possible causes
Symptom
Increase the maximum number of
LUNs per device the operating sys-
tem is configured to see. To change
the maximum LUN per device set-
ting:
•
For Microsoft Windows—See
http://support.microsoft.com/
default.aspx?scid=kb%3ben-
us%3b310072
.
•
For HP-UX—The value can only
be changed for HP-UX versions
11.31 and later. Increase the
number of LUNs per bus on the
HP-UX server by entering
#
scsimgr set_attr -a
max_lunid=32
. You can view
the connected IO by entering
#
ioscan -m lun
.
You cannot create legacy DSFs
for LUN IDs above 7; use per-
sistent device special files in-
stead.
See the HP-UX documentation
for more information.
•
For other operating sys-
tems—See the operating system
web site.
There are more LUNs on the FC
host ports than the operating system
is configured to see. Once the
maximum number of LUNs on a
device is detected, the operating
system stops looking for more
LUNs. In the case of the VLS, the
operating system considers each
FC host port to be one device. So,
if the maximum number of LUNs an
operating system is configured to
see is eight, the operating system
will only see LUN0, LUN1, ...,
LUN7 and will not see LUN8,
LUN9, ..., and up on each FC host
port. By default Windows and HP-
UX hosts can see a maximum of 8
LUNs per FC host port.
Some of the virtual devices are not
detected by the operating system
when it scans the SAN for new
hardware.
HP StorageWorks
311
Summary of Contents for StorageWorks 6000 - Virtual Library System
Page 26: ...Introduction 26 ...
Page 70: ...Storage Configuration 70 ...
Page 116: ...Automigration Replication 116 ...
Page 132: ...Operation 132 ...
Page 140: ...User Interfaces 140 ...
Page 178: ...Management 178 ...
Page 256: ...Component Identification 256 ...
Page 300: ...Component Replacement 300 ...
Page 310: ...Support and Other Resources 310 ...
Page 326: ...Specifications 326 ...
Page 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Page 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Page 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Page 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Page 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Page 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Page 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Page 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Page 348: ...Glossary 348 ...
Page 358: ...358 ...