The
4062UX
W/O
D
VM
The
4062UX
W/O
(without)
D
VM
test
pro
vides
ten
subtests
for
v
erifying
SWM,
DCS,
CMU,
and
CMU84
op eration.
T
able
6-2
lists
the
subtests
and
pro
vides
a
description
of
the
tests
and
the
equipmen
t
needed.
The
PV4062
program
is
completely
in
teractiv
e
and
pro
vides
t
w
o
test
mo
des:
sequen
tial
and
single.
In
the
sequen
tial
test
mo
de,
PV4062
p erforms
eac
h
subtest
in
the
sequence
listed
in
T
able
6-2 .
In
the
single
test
mo
de,
tests
can
b e
p erformed
individually
in
an
y
desired
sequence.
F
or
b oth
test
mo
des,
PV4062
displays
a
running
record
of
test
results.
This
section
pro
vides
instructions
for
p erforming
subtests
of
the
4062UX
W/O
D
VM
in
the
se
quential
test
mo
de
only
.
F
or
more
details
on
eac
h
test
and
for
system
troublesho
oting
pro cedures,
refer
to
the
HP
4062
Servic
e
Manual
.
T
able
6-2.
Subtests
of
the
4062UX
W/O
D
VM
Subtest
Description
48-pin
SWM
96-pin
SWM
Relay
T
est
T
ests
all
rela
y
op erations
on
the
SWM
pin
b oards.
1
HP
16075A
HP
16355A
SMU
T
est
P
erforms
the
DCS
self-test
and
c
hec
ks
SMU
accuracy
(four
SMUs).
HP
16346B
HP
16366A/B
VS
T
est
Chec
ks
the
DCS
VS1
and
VS2
accuracy
.
HP
16346B
HP
16366A/B
VM
T
est
Chec
ks
the
DCS
VM1
and
VM2
accuracy
.
HP
16346B
HP
16366A/B
AFU
T
est
P
erforms
an
analog
feedbac
k
measuremen
t
using
the
DCS
AFU,
and
c
hec
ks
measuremen
t
results
against
test
limits.
HP
16346B
HP
16366A/B
CMS
C-G
T
est
2
P
erforms
the
CMU
ROM/RAM
T
est,
c
hec
ks
C-G
measuremen
t
accuracy
,
and
measures
measuremen
t
pins'
residual
capacitance.
HP
16346B
HP
16366A/B
CMS
Bias
T
est
2
Chec
ks
the
CMU
internal
dc
bias
source
accuracy
.
HP
16346B
HP
16366A/B
CMU84
C-G
T
est
3
Chec
ks
C-G
measuremen
t
accuracy
,
and
measures
residual
capacitance
of
the
measuremen
t
pins.
HP
16346C
HP
16366B
CMU84
Bias
T
est
3
Chec
ks
the
internal
dc
bias
source
accuracy
of
the
CMU84.
HP
16346C
HP
16366B
DC
Leak
T
est
Measures
the
SWM
dc
leak
age
curren
t.
HP
16066A
HP
16370A
1
If
your
system
is
equipp
ed
with
a
96-pin
SWM,
input
relays
are
also
tested.
If
your
SWM
has
a
p
ort
expander,
the
p
ort
expander
relays
are
also
tested.
2
If
the
HP
4280A
CMU
is
present
in
your
system
and
is
connected
to
the
SWM
prop
erly
,
this
test
is
p
erformed.
3
If
the
HP
4284A
CMU84
is
present
in
your
system
and
is
connected
to
the
SWM
prop
erly
,
this
test
is
p
erformed.
6-8
System
V
erification
Summary of Contents for HP 4062F
Page 13: ...B 2 Printer Con guration Softkey Map B 3 Contents 7 ...
Page 18: ......
Page 34: ......
Page 46: ......
Page 60: ...Figure 4 5 Installing the HP 4280A 4 14 System Installation ...
Page 63: ...Figure 4 7 Attaching Rack Flanges for HP 4284A System Installation 4 17 ...
Page 95: ...Figure 5 1 Installation Flowchart for HP 4062UX F System Software Software Installation 5 3 ...
Page 105: ...1140 HF7 PG41 1150 HF8 PG42 1160 HF9 PG51 1170 HF10 PG52 Software Installation 5 13 ...
Page 112: ......
Page 135: ...Figure 6 27 An Example Page of View Result Printer System Verification 6 23 ...
Page 159: ...Figure 6 49 An Example Page of View Result Printer System Verification 6 47 ...
Page 160: ......
Page 162: ......
Page 168: ......
Page 173: ...Error when reading from or writing to a le Installation Problems You May Encounter C 5 ...
Page 174: ......