Shell> info io
I/O INFORMATION
BOOTABLE DEVICES
Order
Media Type
Path
-----
----------
---------------------------------------
1
CDROM
Acpi(HWP0002,PNP0A03,0)/Pci(2|1)/Usb(0, 0)/CDROM(Entry0)/HD(Part1,Sig00000000)
2
HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C5000034749D,Lun0)/HD(Part1,Sig4EE76936-BE45-47FA-9AC7-B0ECF2D912F2)
3
HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part1,Sig92C8CB4C-E0F2-11DA-8002-D6217B60E588)
4
HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part3,Sig92C8CB7E-E0F2-11DA-8004-D6217B60E588)
Seg
Bus
Dev
Fnc
Vendor
Device Slot
#
#
#
#
ID
ID
#
Path
---
---
---
---
------
------
---
-----------
00
00
01
00
0x103C
0x1303
XX
Acpi(HWP0002,PNP0A03,0)/Pci(1|0)
00
00
01
01
0x103C
0x1302
XX
Acpi(HWP0002,PNP0A03,0)/Pci(1|1)
00
00
01
02
0x103C
0x1048
XX
Acpi(HWP0002,PNP0A03,0)/Pci(1|2)
00
00
02
00
0x1033
0x0035
XX
Acpi(HWP0002,PNP0A03,0)/Pci(2|0)
00
00
02
01
0x1033
0x0035
XX
Acpi(HWP0002,PNP0A03,0)/Pci(2|1)
00
00
02
02
0x1033
0x00E0
XX
Acpi(HWP0002,PNP0A03,0)/Pci(2|2)
00
14
01
00
0x1000
0x0054
01
Acpi(HWP0002,PNP0A03,400)/Pci(1|0)
00
14
02
00
0x1000
0x0054
02
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)
00
15
01
00
0x1000
0x000F
07
Acpi(HWP0002,PNP0A03,500)/Pci(1|0)
00
15
01
01
0x1000
0x000F
07
Acpi(HWP0002,PNP0A03,500)/Pci(1|1)
00
15
02
00
0x8086
0x1079
08
Acpi(HWP0002,PNP0A03,500)/Pci(2|0)
00
15
02
01
0x8086
0x1079
08
Acpi(HWP0002,PNP0A03,500)/Pci(2|1)
Fast initialization: Enabled
System Wake-On-LAN:
Enabled
Shell>
Devices, such as USB ports, that do not occupy a slot are referenced as being in slot
XX
.
Slots that do not contain an I/O card will not be listed in the output. Using the output, confirm
that a device detected in each slot that is populated.
13. Installing the OS
HP-UX, Windows, and Linux require reinstallation of the OS with the upgrade of the IOBP.
See
for more information.
14. Booting to the Operating System
See
for this procedure.
Installing Core I/O Cards
WARNING!
To reduce the risk of personal injury from hot surfaces, allow the internal system
components to cool before touching them.
CAUTION:
To reduce the risk of personal injury or damage to the equipment, consult the safety
information and user documentation provided with the server before attempting the installation.
Many servers are capable of producing energy levels that are considered hazardous and are
intended to be serviced only by qualified personnel who have been trained to deal with these
hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided
for the purpose of removing these hazardous conditions.
CAUTION:
Electrostatic discharge (ESD) can damage electronic components. Be sure that
you are properly grounded before beginning this procedure.
CAUTION:
When working with equipment installed in a rack, be sure that the equipment and
rack are stable before beginning the installation procedure.
268