114 Intelligent blades
3.
Check the port LEDs to verify that all components are functional. For information about LED patterns,
see ”
Monitor system components
” on page 33.
4.
Log in to the Director as
admin
.
5.
Verify the correct operation of the FC4-16IP blade ports by typing the
switchShow
command from the
Director command prompt. This command provides information about switch and port status.
Recommendations for cable management
Cables can be organized and managed in a variety of ways, such as by using cable channels or patch
panels, as follows:
•
Plan cable management before installing the blade.
•
Leave at least one meter of slack for each port cable. This provides room to remove and replace the
blades, and helps prevent the cables from being bent to less than the minimum bend radius.
sw48000:admin> switchshow
switchName: sw48000
switchType: 42.2
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 15
switchId: fffc0f
switchWwn: 10:00:00:60:69:80:47:74
AD Feature: Active
Current AD: 0
zoning: ON (SIMPLE_CFG)
switchBeacon: OFF
blade1 Beacon: OFF
blade2 Beacon: OFF
blade3 Beacon: OFF
blade7 Beacon: OFF
blade9 Beacon: OFF
blade10 Beacon: OFF
Index Slot Port Address Media Speed State Proto
===================================================
112 10 0 0f7000 id N4 No_Light Disabled (Persistent)
113 10 1 0f7100 -- N4 No_Module Disabled (Persistent)
114 10 2 0f7200 -- N4 No_Module Disabled (Persistent)
115 10 3 0f7300 -- N4 No_Module Disabled (Persistent)
116 10 4 0f7400 -- N4 No_Module Disabled (Persistent)
117 10 5 0f7500 -- N4 No_Module Disabled (Persistent)
118 10 6 0f7600 -- N4 No_Module Disabled (Persistent)
119 10 7 0f7700 id N4 No_Light Disabled (Persistent)
10 ge0 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge1 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge2 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge3 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge4 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge5 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge6 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge7 -- 1G No_Sync ISCSI Disabled (Persistent)
sw48000:admin>
Summary of Contents for A7990A - StorageWorks SAN Director 4/16 Blade Switch
Page 8: ...8 ...
Page 62: ...62 Monitor system components ...
Page 100: ...100 Installing Field replaceable units FRUs ...
Page 122: ...122 Intelligent blades ...
Page 132: ...132 Regulatory compliance and safety notices ...
Page 134: ...134 Port numbering templates 26390a ...
Page 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Page 136: ...136 Port numbering templates 26388a ...
Page 140: ...140 Port numbering templates ...