DC SAN Backbone Director hardware reference guide
95
This
switchShow
command displays DC Director and port status information.
rsl8-st03-dcx-1:admin>
switchshow
switchName: rsl8-st03-dcx-1
switchType: 62.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 11
switchId: fffc0b
switchWwn: 10:00:00:05:1e:39:59:67
zoning: OFF
switchBeacon: OFF
blade3 Beacon: OFF
blade5 Beacon: OFF
blade8 Beacon: OFF
blade10Beacon: OFF
Index
Slot
Port
AddressMediaSpeedStateProto
===========================================================
32
3
0
0b2000idN4OnlineL-Port 5 public
33
3
1
0b2100__N8No_Module
34
3
2
0b2200__N8No_Module
35
3
3
0b2300__N8No_Module
36
3
4
0b2400idN4OnlineF-Port
10:00:00:00:c9:51:00:2d
37
3
5
0b2500__N8No_Module
rsl8-st03-dcx-1:admin>
4.
Verify that all the IP address information is correct by typing
ipAddrShow
and checking the results
against the IP information recorded in the “config-miscinfo.txt” file.
rsl8-st03-dcx-1:admin>
ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin>
Summary of Contents for A7990A - StorageWorks SAN Director 4/16 Blade Switch
Page 8: ...8 ...
Page 62: ...62 Monitor system components ...
Page 100: ...100 Installing Field replaceable units FRUs ...
Page 122: ...122 Intelligent blades ...
Page 132: ...132 Regulatory compliance and safety notices ...
Page 134: ...134 Port numbering templates 26390a ...
Page 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Page 136: ...136 Port numbering templates 26388a ...
Page 140: ...140 Port numbering templates ...