74
Installing Field-replaceable units (FRUs)
If not, POST is not complete or the CP blades have not achieved redundancy. Wait one or two minutes
and re-enter the command until you can verify that redundancy has been achieved.
4.
Type
slotShow
. The command output shows the new CP blade as “enabled”:
swDir:admin> slotShow
Slot Blade Type ID Status
---------------------------------
1
SW BLADE 16 ENABLED
2
SW BLADE 16 ENABLED
3
SW BLADE 16 ENABLED
4
SW BLADE 16 ENABLED
5
CR BLADE 17 ENABLED
6
CP BLADE 18 ENABLED
7
CP BLADE 18 ENABLED
8
CR BLADE 17 ENABLED
9
SW BLADE 16 ENABLED
10
SW BLADE 16 ENABLED
11
SW BLADE 16 ENABLED
12
SW BLADE 16 ENABLED
swDir:admin>
5.
Type
firmwareShow
to determine the Fabric OS version.
This example shows sample output for the
firmwareShow
command:
swDir:admin>
firmwareShow
Local CP (Slot 7, CP1): Active
Primary partition: v6.0.0
Secondary Partition: v6.0.0
Remote CP (Slot 6, CP0): Standby
Primary partition: v6.0.0
Secondary Partition: v6.0.0
Note: If Local CP and Remote CP have different versions
of firmware, please retry firmwaredownload command.
swDir:admin>
6.
If the firmware version on the replacement blade does not match that on the active CP blade, bring the
replacement blade to the same firmware level as the active blade.
Summary of Contents for A7990A - StorageWorks SAN Director 4/16 Blade Switch
Page 8: ...8 ...
Page 62: ...62 Monitor system components ...
Page 100: ...100 Installing Field replaceable units FRUs ...
Page 122: ...122 Intelligent blades ...
Page 132: ...132 Regulatory compliance and safety notices ...
Page 134: ...134 Port numbering templates 26390a ...
Page 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Page 136: ...136 Port numbering templates 26388a ...
Page 140: ...140 Port numbering templates ...