70
Installing Field-replaceable units (FRUs)
Control processor blade (CP8)
This section describes how to remove and replace a control processor (CP8) blade. Each DC Director has
two CP8 blades located in slot 6 and slot 7.
NOTE:
If the new CP blade does not have the same firmware as the active CP blade, you must upgrade
the new blade to the active CP blade’s firmware version.
The replacement procedure for the CP blade takes approximately 30 minutes. The following items are
required for the CP blade replacement:
•
ESD grounding strap
•
Workstation computer
•
Serial cable
•
IP address of an FTP server for backing up the DC Director configuration
•
Phillips #2 screwdriver
•
Replacement CP blade. Requires the DC Director CP blade (CP8).
How to determine whether or not to replace a CP blade
Confirm that you need to replace the CP blade. The following events might indicate that a CP blade is
faulty:
•
The status LED on the CP blade is lit amber, or the power LED is not lit.
•
The CP blade does not respond to Telnet commands, or the serial console is not available.
•
The
slotShow
command does not show that the CP blade is enabled.
•
The
haShow
command indicates an error.
•
The clock is inaccurate, or the CP blade does not boot up or shut down normally.
•
Any of the following messages display in the error log:
•
Slot unknown
message relating to a CP slot
• CP blade errors or I
2
C timeouts
• FRU: FRU_FAULTY messages for a CP blade
• Configuration loader messages or
Sys PCI config
messages
• Generic system driver messages (“FABSYS”)
• Platform system driver messages (“Platform”)
• EM messages that indicate a problem with a CP blade
• Function fail messages for the CP master
For more information about error messages, refer to the
Fabric OS Message Reference
.
Recording critical DC Director information
Back up the DC Director configuration before you replace a CP blade. Refer to the
HP StorageWorks
Fabric OS 6.x administrator guide
for backup information.
To record critical DC Director information:
1.
Login to the functioning CP blade as admin, using either a Telnet or a serial console connection.
2.
Type
haShow
to determine which CP blade is active:
swDir:admin> haShow
Local CP (Slot 7, CP1) : Active
Remote CP (Slot 6, CP0) : Standby, Healthy
HA Enabled, Heartbeat Up, HA State Synchronized
Summary of Contents for A7990A - StorageWorks SAN Director 4/16 Blade Switch
Page 8: ...8 ...
Page 62: ...62 Monitor system components ...
Page 100: ...100 Installing Field replaceable units FRUs ...
Page 122: ...122 Intelligent blades ...
Page 132: ...132 Regulatory compliance and safety notices ...
Page 134: ...134 Port numbering templates 26390a ...
Page 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Page 136: ...136 Port numbering templates 26388a ...
Page 140: ...140 Port numbering templates ...