Installing Field-replaceable units (FRUs)
Blower assembly
IMPORTANT:
To ensure continuous adequate cooling, maintain three operating blower assemblies at all
times except for the brief period when replacing a blower assembly.
The procedure for each blower assembly takes less than 5 minutes. The following items are required for the
blower assembly replacement:
•
Replacement blower assembly
•
Phillips #2 screwdriver
Removing a blower assembly
To remove a blower assembly:
CAUTION:
Wear a grounded ESD strap when handling DC Director components. The Director chassis provides a
grounding connection above the power connectors. Also,
store ESD-sensitive components in antistatic
packaging.
1.
Before removing a blower assembly, verify that the other blower assemblies are functioning correctly.
The power LEDs should be steady green.
2.
Use the screwdriver to loosen the captive screws at the top and bottom of blower assembly.
3.
Support the blower assembly from underneath. Use the handle to remove the blower assembly (see
Figure 33
).
Replacing a blower assembly
To replace a blower assembly
1.
Orient the blower assembly and slide it into the chassis, pushing firmly to ensure that it is seated.
2.
Verify that the power LED displays a green light.
3.
Use the screwdriver or your fingers to tighten the captive screws.
Summary of Contents for A7990A - StorageWorks SAN Director 4/16 Blade Switch
Page 8: ...8 ...
Page 62: ...62 Monitor system components ...
Page 100: ...100 Installing Field replaceable units FRUs ...
Page 122: ...122 Intelligent blades ...
Page 132: ...132 Regulatory compliance and safety notices ...
Page 134: ...134 Port numbering templates 26390a ...
Page 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Page 136: ...136 Port numbering templates 26388a ...
Page 140: ...140 Port numbering templates ...