DC SAN Backbone Director hardware reference guide
97
Verify correct configuration of fabric
Copying the command outputs from this section into a file is recommended.
To verify correct configuration of the fabric:
1.
Create an “after” SAN profile by entering the following commands and copying the output to a text file
named “SANafter.txt”:
•
nsShow
•
nsAllShow
•
switchShow
•
fabricShow
rsl8-st03-dcx-1:admin>
nsshow
Type Pid COS PortName NodeName TTL(sec)
N 020f00; 3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
Fabric Port Name: 20:0f:00:60:69:90:03:f0
<output truncated>
rsl8-st03-dcx-1:admin>
nsallshow
{
020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
rsl8-st03-dcx-1:admin>
switchshow
switchName: rsl8-st03-dcx-01
<output truncated>
rsl8-st03-dcx-1:admin>
fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
rsl8-st03-dcx-1:admin>
2.
Determine any differences between the information in the “SANafter.txt” file and the information in the
“SANbefor.txt” file created earlier. In particular, look for differences in the following:
• Device types
• Number of devices
• ISL and port states
• Number of switches in the fabric
Summary of Contents for A7990A - StorageWorks SAN Director 4/16 Blade Switch
Page 8: ...8 ...
Page 62: ...62 Monitor system components ...
Page 100: ...100 Installing Field replaceable units FRUs ...
Page 122: ...122 Intelligent blades ...
Page 132: ...132 Regulatory compliance and safety notices ...
Page 134: ...134 Port numbering templates 26390a ...
Page 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Page 136: ...136 Port numbering templates 26388a ...
Page 140: ...140 Port numbering templates ...