670
Error
−
1311
RF power loss indicates loss of Voice Channel.
When any Call Processing Subsystem screen is displayed (except the
ANALOG MEAS
screen) and the Call Processing Subsystem is in the
Connect
state, the host firmware
constantly monitors the mobile station’s transmitted carrier power. If the power falls
below 0.0005 Watts the simulated Base Station will terminate the call and return to the
Active
state. This error message is displayed if the host firmware has detected that the
mobile station’s carrier power has fallen below the 0.0005 Watts threshold. The call is
dropped and the Call Processing Subsystem returns to the
Active
state.
NOTE:
In order to ensure that the host firmware makes the correct decisions regarding the presence
of the mobile stations’s RF carrier, the Test Set’s RF power meter should be zeroed when
first entering the Call Processing Subsystem (that is - the first time the Call Processing
Subsystem is selected during a measurement session). Failure to zero the power meter can
result in erroneous RF power measurements. See “Conditioning The Test Set For Call
Processing” in the HP 8920 User’s Guide for information on zeroing the RF Power meter
manually or <blue>"Conditioning the Test Set for Call Processing" on page 468 of this
manual for information on zeroing the RF Power meter programmatically.
Error
−
1312
Data from RVC contains invalid bits in word [1,2,3].
Indicates that the decoded data received on the reverse voice channel contains invalid bits
in word 1 and/or word 2 and/or word 3. The raw decoded data is displayed in hexadecimal
format in the top right-hand portion of the
CALL CONTROL
screen. Raw decoded data is
only displayed when the
CALL CONTROL
screen
Display
field is set to
Data.
Error
−
1313
Timeout occurred while in Maintenance state.
Indicates that the simulated Base Station’s internal timer expired before the mobile station
was taken out of the maintenance state. The internal timer is set to 20 seconds when the
maintenance order is sent to the mobile station.
Error
−
1314
Alert attempted while not in Maintenance or Connect state.
Indicates that an attempt was made to send an Alert order to the mobile station when the
Call Processing Subsystem was not in the Maintenance state or Active state.
Summary of Contents for 8920B
Page 10: ...10 ...
Page 16: ...Contents 16 9 Error Messages Index 673 ...
Page 17: ...17 1 Using HP IB ...
Page 48: ...48 Chapter 1 Using HP IB Remote Local Modes ...
Page 49: ...49 2 Methods For Reading Measurement Results ...
Page 61: ...61 3 HP IB Command Guidelines ...
Page 84: ...84 Chapter 3 HP IB Command Guidelines Guidelines for Operation ...
Page 85: ...85 4 HP IB Commands ...
Page 90: ...90 Adjacent Channel Power ACP ...
Page 116: ...116 Configure I O Configure ...
Page 156: ...156 Call Processing ...
Page 185: ...185 System System SYSTem ERRor Returns integer value quoted string ...
Page 242: ...242 Common Command Descriptions ...
Page 251: ...251 5 Advanced Operations ...
Page 377: ...377 7 IBASIC Controller ...
Page 458: ...458 Chapter 7 IBASIC Controller The TESTS Subsystem ...
Page 640: ...640 Chapter 8 Programming The Call Processing Subsystem Example Programs 11280 SUBEND 11290 ...
Page 643: ...643 9 Error Messages ...
Page 672: ...672 ...
Page 682: ...Index 682 ...